Back to Input Deck Cards
Back to SUBSURFACE_GEOPHYSICS
Back to MODE
ERT¶
Defines options for the ERT geophysics mode
SIMULATION Options¶
(under SUBSURFACE_GEOPHYSICS in SIMULATION PROCESS_MODELS block)
Basic Settings
- COMPUTE_JACOBIAN
Toggles on the calculation of the ERT Jacobian (derivatives of ERT measurements with respectd to bulk electrical conductivity).
- NO_ANALYTICAL POTENTIAL
An analytical potential is calculated as the initial guess for the iterative linear solve after calculating an averaged conductvity model. This flag turns the calculation off.
Examples¶
SIMULATION
SIMULATION_TYPE SUBSURFACE
PROCESS_MODELS
SUBSURFACE_GEOPHYSICS geophysics
MODE ERT
OPTIONS
COMPUTE_JACOBIAN
NO_ANALYTICAL POTENTIAL
/
/
/
END